Custom Query (210 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (16 - 18 of 210)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Ticket Resolution Summary Owner Reporter
#64 duplicate STOP sorry: t not in [k] jbrioude sureshraja1
Description

I am getting this error but all my met data is in Kelvin. Is this referring to the met data?

#74 fixed Problem in FLEXPART run with stratospheric ozone tracer option jbrioude sulinust
Description

I have been trying a bunch of test run with FLEXPART-WRF using WRF output data, the results turn out to be reasonable if I set mdomainfill to be 0, but the output concentrations are all 0 if I choose stratospheric ozone tracer option (mdomainfill=2), so I am wondering if anyone could help find out what the problem is, please find the model configuration attached, any help is very much appreciated.

#117 fixed Output unit of backward simulation for stratospheric ozone tracking jbrioude sulinust
Description

As there are three output unit for backward simulation, s, s kg/m3 and s m3/kg, how can I get mixing ratio such as ppb and ppb, in backward simulation for stratospheric ozone tracking?

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Note: See TracQuery for help on using queries.