Ignore:
Timestamp:
Aug 12, 2020, 8:47:31 AM (4 years ago)
Author:
Anne Philipp <anne.philipp@…>
Branches:
master, ctbto, dev
Children:
73308e0
Parents:
ee9aaec
Message:

updated online docu (rm tabs)

File:
1 edited

Legend:

Unmodified
Added
Removed
  • For_developers/Sphinx/Source/Support/known_bugs_issues.rst

    r8a53342 r08c9091  
    3131.. code-block:: bash
    3232
    33         ECCODES ERROR   :   wrong size (184) for pv it contains 276 values
    34         ECCODES ERROR   :  get: pv Passed array is too small
    35         ... ERROR CODE: 250
    36         ... ERROR MESSAGE:
    37                 Command '['<path-to-flex_extract>/flex_extract_v7.1/Source/Fortran/calc_etadot']' returned non-zero exit status 250.
    38         ... FORTRAN PROGRAM FAILED!
     33    ECCODES ERROR   :   wrong size (184) for pv it contains 276 values
     34    ECCODES ERROR   :  get: pv Passed array is too small
     35    ... ERROR CODE: 250
     36    ... ERROR MESSAGE:
     37          Command '['<path-to-flex_extract>/flex_extract_v7.1/Source/Fortran/calc_etadot']' returned non-zero exit status 250.
     38    ... FORTRAN PROGRAM FAILED!
    3939
    4040then you have set a wrong maximum level in the :literal:`CONTROL` file!
     
    4848.. note::
    4949 
    50         Be aware that the ECMWF model counts the levels from the top of the atmosphere downward to the surface. Level 1 is the topmost level, and e.g. 137 would be the level closest to the ground.
     50     Be aware that the ECMWF model counts the levels from the top of the atmosphere downward to the surface. Level 1 is the topmost level, and e.g. 137 would be the level closest to the ground.